GX Series High reliability ultrasonic open channel flow meter

GX Series High reliability ultrasonic open channel flow meter

share
  • Detail
  • Parameters

1. Application field

Ultrasonic open-channel flow meter is used with weir tank to measure the water flow rate in the open-channel. This meter is mainly used to measure sewage plants, sewage outfall of enterprises and institutions, city sewer flows and irrigation channels.

As the meter use the ultrasonic wave through air do the measurement with a non-contact method. Therefore, the meter has a higher reliability than other forms of the instrument, when under the dirt, corrosive liquids case.

2. Specification

Function

Integrate type

Split type

Measuring range

0.1L/s~99999.99m3/h

Cumulative flow

Max. 4290000000.00m3

Max Level range

3m

Level Accuracy

0.5%

Resolution

3mm or 0.1%

Flow accuracy

Standard weir notch 1%~5%

Non-standard 10~30%

Display

Chinese LCD

Analog output

0-5V 0-10V  4~20mA with hart

Relay output

2 sets AC 220V/ 8A or DC 30V/ 5A

Power

12VDC, battery, or solar energy optional

Ambient temp.

Display meter -20~+60°C,probe -20~+80°C

Communication

485,232 , MODBUS protocol (optional)

Working pressure

Standard atmospheric pressure

Working environment humidity

90%RH, Non condensation

Protection grade

Meter IP67,probe IP68

Meter IP65,probe IP68

Probe cable

None

Can be 100m

Probe installation

M48X2mm thread+ nut, flange mounting(diameter of flange blind plate should be 50mm ),

Probe material

ABS standard, PTEF for corrosive environment